Products
0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD

0.75-2.2kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD

0,75-2.2kW 3 Phase 380V Solaris Pump et Propositum Generale Inverter VFD componit sentinam photovoltaicam cum potestate in conventionali variabili-frequency motrix potestate in uno suggestu iMaster VFD-PC10. Pro fabrica in Sinis, CSIVEI 380 V exempla tria phase instruit cum MPPT investigationibus ad crepitum solaris, ultra SVC/V/F imperium, in PID et Modbus RTU constructum ad applicationes generales. 900 VDC maximum initus sustinet figurarum simplicium chordarum ordinatarum quae huic amplitudini enumeratae sunt. Coniunge nos ad exemplar lectionis, figurae moduli et scntentiae.

Csivei officinarum 0.75-2.2kW 3 Phase 380V Solaris Pump et Propositum Generalis Inverter VFD features altae intentionis DC input range. Maximum DC initus est CM VDC, cum commendatione apertae intentionis ambitus 550-750 VDC et MPPT amplitudinis 450-600 VDC. Apta initium intentionis range est 300-900 VDC. Hi valores praebent fundamentum ad chordas tabulae eligendas quae in mensa ordinata commendatur.

Series tria motorum ratings comprehendit: 0.75 kW, 1.5 kW et 2.2 kW. Eorum excursus aestimati sunt 2.1 A, 3.8 A et 5.1 A respectively. Unumquodque exemplar designatum est ad tres phase 380 V AC supplendum et etiam operari potest cum ordinata photovoltaica recte conformata in mode sentinae solaris. Electio modus operandi decernit utrum coegi adhibeatur ad flare solaris an inverto generali proposito.

Ad optiones moduli inscriptae, suadeo ordinata utitur una chorda 18 modulorum 250 W (37±1 V) vel una chorda 15 modulorum apud 300 W aestimata (45±1 V). Altius PV chorda voltagium potest significare inferiorem DC currentem pro gradu potentiae datae, quae adiuvat ut funem currentem et guttam voltationis longioris currens administrare possit. Finalis chorda designandi moduli electricis notitia actuali uti debet et maximam voltage open-circuitorum ordinata intra limitem coegi.

In tribus exemplaribus chassis compactionis mensurae 171 × 86 138 mm communicant et pondo circiter 1 kg. Vestigium ascensum 67.3 × 157.5 mm adiuvat in inverto aptare in minora repositoria vel clausuras armorum. Haec forma compacta utilis est ubi parva sentinam vel machinam celeritas variabilis eget sed spatium institutionis limitatur.

Duo operans modos in unum Drive

Solaris Pump Modus

Cum P8-00 statuto ad 1, coegi in mode sentinam solarem operatur. MPPT semita adaptat operationem in responsione ad potentiam photovoltaicam promptam, cum logicae et sentinae tutelae relatae infirmae functiones adiuvant ad mutandas condiciones solares administrandas. Ordinata chorda voltage, ratings ac sentinae requisita omnia reprimenda sunt cum systema specificando.

General-Propositum Inverter Modus

Cum P8-00 statuto ad 0, eadem ferramenta adhiberi possunt ad tres periodos motores compatibile sine apparatu solaris. SVC vel V/F imperium sustinet ordinationem mobilitatis motoris, dum in PID et RS485 Modbus RTU constructa praesto sunt applicationes aptae pressionis, fluxus vel processus moderaminis. CSIVEI configurare potest modum rogatum operandi antequam sit amet; modus posterior mutatur per ambitum pertinentes et sequi debet opus manuale.

Specifications

Tabula A. Exemplar ratings

Item VFD-PC10-0.75G-T4 VFD-PC10-1.5G-T4 VFD-PC10-2.2G-T4
Lorem motricium 0.75 kW / 1 HP 1.5 kW / 2 HP 2.2 kW / 3 HP
Facultatem nominalem 1.5 kVA 3 kVA 4 kVA
Input current 3.4 A 5 A 5.8 A
Output current 2.1 A 3.8 A 5.1 A
AC input voltage AC 3 PH 380 V (-15%) ad 440 V (+10%).
Maximilianus. DC input voltage 900 VDC
Commendatur Voc range 550 ad 750 VDC
Commendatur MPPT range 450 ad 600 VDC
Satus range voltage 300 ad 900 VDC, modulus aptabilis
Rated output voltage 3 PH 380 V AC
sonitus gradu 50 dBA max.

Mensa B. Commendatur ordinata solis

Exemplar 37±1 V modulorum, 250 W±5 Wp 45±1 V modulorum, 300 W±5 Wp
Moduli per chorda Strings Moduli per chorda Strings
VFD-PC10-0.75G-T4 18 1 15 1
VFD-PC10-1.5G-T4 18 1 15 1
VFD-PC10-2.2G-T4 18 1 15 1

Tabula C. Specificationes generales (eadem trans range iMaster)

Item Specification
Rated frequency 50/60 Hz
Input frequency range ±5% (47.5 ad 63 Hz)
Output voltage 0 initus est voltage
Output frequency 0.1 ad 500 Hz
Maximam frequentiam 0 ad 500 Hz (SVC et V/F imperium)
Portitorem frequency 0,8 kHz ad 8 kHz, adaequatum statim ad onus (usque ad 16 kHz sustentatur)
Frequentia resolutio Digital setting 0.01 Hz; Analog occasum 0.025% of maximum frequency
Imperium modus Insipiens vector imperium (SVC); V/F imperium
Satus torques 0.5 Hz / 150% (SVC)
Celeritas range 1:100 (SVC)
Celeritas stabilitatis veritas ±0.5% (SVC)
ONERO facultatem 150% monetae æstimaturæ pro 60 s; 170% pro XII s; CXC% ad 1.5 s
Torque boost Automatic Aureus boost; manual boost 0.1% ad 30.0%
V/F curva Lineae, punctum multi- et curvae quadratae (1.2 / 1.4 / 1.6 / 1.8 / 2.0 potentiae)
V/F separation Plena separatio, dimidium separationis
Acceleratio / retardatio Linearibus vel S-curvis, 0.0 ad 6500.0 s
DC braking Committitur frequentia 0.00 Hz ad maximam frequentiam; tempus 0.0 ad 36.0 s; current 0.0% ad 100.0%
JOG imperium JOG frequentia 0.00 ad Hz frequentiam maximam (default 5 Hz); accel/decel 0.0 ad 6500.0 s
Inaedificata PID Ita, pressionis, fluxus vel temperatus ansa clausa sine exteriori moderatore
AVR Output voltage tenuit firmum, cum eget voltage fluctuat
Input terminals 5 digitalis inputs, DI5 sustinet pulsum venae altae usque ad 50 kHz; 1 analog input 0-10 V vel 0-20 mA; 1 keypad potentiometer input
Output terminals 1 pulsus summus velocitate output usque ad 50 kHz; Nullam 1 output; I Analog output 0-20 mA seu 0-10 V *
Communicationis RS485, Modbus RTU
Praesidium Motor brevis-circuitus deprehensio in potentia in, output phase damnum, super-currente, supra intentione, sub intentione, supra temperatura, onero, underload, lux debilis
operating temperatus -10°C ad 50°C; derate I% per I ° C supra XL ° C *
Repono temperatus -20°C ad 60°C
Umor Infra 95% RH, nulla condensatio
altitudo Infra M m; derate 1% per 100 m ab 1000 ad 3000 m
Vibratio Infra 5.9 m/s² (0.6 g)
clausura IP20, murus mons vel scrinium, vertical installation
Distributio systematis TN, TT
EMC / salus IEC 61800-3 (C3); IEC 61800-5-1

Typical Applications

Haec vis extensionis destinata est ad minores tres phases soleatus et instrumentum motoris agitatum ubi celeritas aptabilis, operatio solaris vel utraque utilis est.

  • CONSERVATORIUM et systemata polytunnel:  irrigationes soleatus repelle et VENTILATIO compatibilis nisl in copia trium phase.
  • Pomum et vineae irrigationes: Regula sentinam velocitatem in systematibus destillationibus supplevit per borreolum vel piscinam repositam.
  • Aquae communitatis parva puncta: Operi soleatus qui aquam transferunt de fonte in piscinam repositam elevatam.
  • Aquae culturae et landscape features: Imperium circulatio, aquae commutatio vel fons soleatus ubi motor rating coegi aequet.
  • Officinam et apparatum industrialem levem:  controlare processus soleatus compatibilis, instrumentorum circulationes coolant et compressores modici in genere proposito.
  • Ad systemata sentinam, acceleratio et retardatio aptabilis adiuvare potest ratem administrare ad quem fluunt aedificat et cadit. Recta aggeris occasus pendent sentinarum, pipework et hydrau-licae conditiones; eligantur in committendo magis quam ex sola potestate motore assumptae.

    Technical volutpat

    900 VDC Input pro Una String Array

    Commendatae conformationes ordinatae utuntur 18 modulis ad 250 W vel 15 modulorum ad 300 W in una chorda. Inversus sustinet usque ad 900 VDC, cum commendatione Voc vagandi 550-750 VDC et MPPT amplis 450-600 VDC. Reprehendo moduli actuales voltage open-circuitus sub situ temperaturae condiciones antequam filum confirmans.

    Solaris Pump et General-Propositum Modi

    Pone P8-00 ad 1 ad sentinam solarem modum seu 0 pro generali-proposito modo. Idem suggestum MPPT fundatum crepitum solaris cum SVC/V/F potestate motoris coniungit, in PID et Modbus RTU constructum, permittens id ut aptae sentinae vel levium applicationum machinis inserviat.

    Infirmi-Lux et Pump Praesidium functiones

    P8-10 ad P8-14 configurare lux infirma-siste et sileo mores. Tutela Underload et aquae gradus initibus etiam praesidium sentinam tueri possunt cum recte wired ac conformatus ad institutionem.

    Foedus Frame cum Integrated Control

    The 171 × 86 × 138 mm gb pondo circiter 1 kg. Inaedificata in PID, quinque initibus digitalibus, analog I/O et RS485 Modbus RTU localem potestatem et integrationem optiones praebent, quin requirat moderatorem separatum PID ad applicationes clausuras sustentandas.

    FAQ

    Quot tabulae pro 2.2 kW tres-phase sentinae?

    18 moduli 250 W (37 V typus) in uno chorda, seu 15 modulorum 300 W (45 V typus). Utraque terra instructa intus commendata 550 ad 750 VDC patens ambitus patet. Nolite excedere 900 VDC, quod est maximum aestimatum.

    Potestne currere tres-phases sentinae cum nulla elaboratione connexionis omnino?

    Ita, id est normalis off-eget setup. Filum ordinatae ad DC terminales et sentinam ad U, V et W, pone P8-15 ad 1 pro copia solari, et agitatio currit quoties ordinata satis intentione liberat.

    Eget encoder vel separatum sentinam moderatoris?

    Neque. Imperium sensorium vector vel V/F est, utrumque sine responso. MPPT, praesidium sicco-currendum, praesidium underload et ad libitum PID pro constanti pressione iam in activitate sunt.

    Quid est infima frequentia in sentinam curret?

    P8-09 terminum inferiorem frequentiae operandi ponit, 10.00 Hz per defaltam. Una cum debili levi limine in P8-10, id est quod resistit coegi ne sentinam tardius ad aquam movendam.

    Possum monitor remotius?

    Plus RS485 cum Modbus RTU, sic. Frequentia operans, bus voltage, output current, output potestas, DI et DO status et modus copiae hodiernae omnes lectabiles sunt ab U0 globo vigilantia, cum copia modi apud U0-49 ostendens eget vel solaris.

    Laborat nullo apparatu solaris omnino?

    Ita. Magna pars huius magnitudinis naves in communi-proposito modo, mittentes fans CONSERVATORIUM, officinae soleatus, circulationem coolant et compressores parvae in 380 V copia cum nullo usquam in situ ordinatae sunt. Eodem ferramento, eodem parametro, alius modus. Dic quem vis cum iubes. Unitas empta in sentinarum solaris modus transmutatur, ponendo P8-00 ad 0 .

    Quid est plumbum in mixto ordine temporis?

    Indica nobis exemplar mix et quantitatis et scribendo pretio diem navem citamus. Standard ratings et OEM-notatae unitates in eadem schedula non navem faciunt, quia casus imprimendi ac pittacia artificio tuo fiunt, ideo diiudicandum est quod ante iubes.

    Mitte Inquisitionem
    Contactus info

    Si inquisitionem habes de quotation vel de cooperatione, placet liberum contactus nobis electronicum facere in sanchia@csivei.com vel sequenti forma inquisitionis utere. Repraesentator venditio nostra intra 24 horas contact erit. Gratias tibi ago pro cura tua in productis nostris.


    Whatsapp:8615705777705

    Tela:www.csiveivfd.com


    X
    Crusulis utimur ut meliorem experientiam pasco tibi praebeamus, situm negotiationis et personalize contentus analyse. Hoc situ utendo, ad nostrum crustulorum usum consentis. Privacy Policy
    RejectAccipe