Products
7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD
  • 7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD

7.5kW/11kW 3 Phase 380V Solaris Pump et Consilium Generale Inverter VFD

7.5kW/11kW 3 Phase 380V Pump Solaris et Inverter VFD Generalis Finis oblatus emptum CSIVEI officinas iMaster subsidia solari flare et imperium motoris ad 7.5 kW et 11 kW applicationes generales sustinet. Series linearum VFD-PC10 MPPT, SVC et V/F imperium constructum in PID, RS485 Modbus RTU, munia tutelae pro conditionibus input, oneris et oneris solaris inclusis. Exemplaria 7.5 kW et 11 kW praebent excursus censitorum 17 A et 25 A respective aestimatos.

CSIVEI iMaster VFD-PC10 series comprehendit VFD-PC10-7.5G-T4 et exempla VFD-PC10-11G-T4-MK ad tria phase 380 V applicationes. Excursus recensiti sunt 17 A ad 7.5 kW exemplar et 25 A pro 11 kW exemplar. Ambae aestimationes adhibentur in systematibus solis-powered flantibus et applicationibus motoriis industrialibus compatibilibus, subiectis electricis specificationibus electae coegi.

In mode sentinae solaris, 7.5kW/11kW 3 Phase 380V Pump Solaris et Inverter Generalis VFD potentia DC utitur ex ordinata photovoltaica et maximam vim in puncto tracking (MPPT) applicat ad motorem secundum initus solaris praesto. In communi-proposito modo, imperium mobiles frequentiae variabiles praebet ad exhauriendas exhauriendas et alia instrumenta componenda. Modus operandi per modulum P8-00 eligitur secundum applicationem debitam et configurationem suppletam.

Comparatus cum moderatore fundamentali velocitatis motoriis, functiones PC10 numeratas etiam includunt vigilantia aqua graduum, deprehensio underload deprehensio et renuntiatio probe culpae. Munera haec ad systemata flare pertinentes ubi fons aquae, piscinae et sentinae operationes repositae per coegi monitores debent esse.

Exemplar Specifications

Tabula A. Exemplar ratings
Item VFD-PC10-7.5G-T4 / -MK VFD-PC10-11G-T4-MK
Lorem motricium 7.5 kW / 10 HP 11 kW / 15 HP
Facultatem nominalem 15 kVA 30 kVA
Input current 18.9 A 27.8 A
Output current 17 A 25 A
AC input voltage AC 3 PH 380 V (-15%) ad 440 V (+10%).
Maximilianus. DC input voltage 900 VDC
Commendatur Voc range 550 ad 750 VDC
Commendatur MPPT range 450 ad 600 VDC
Satus range voltage 300 ad 900 VDC, modulus aptabilis
sonitus gradu 65 dBA max.

Exemplar elige, comparando currenti motoris aestimati cum rating inverti currentis, quam soli potentiae motoriae freti. Confirma exemplum accuratum suffixo, inputa intentione requisita ac data applicabilium nominatorum ante institutionem.

Commendatur Solaris Forum configurationis

Figurarum relatio infra ostende quantitates moduli pro duobus aestimationes coegi enumeratas. Principium rei praebent ad PV systema designandum; finalis dispositio verificabitur contra notas electricas moduli electas, temperaturas minimas situs et requisita flare.

Exemplar 37±1 V modulorum, 250 W±5 Wp 45±1 V modulorum, 300 W±5 Wp
Moduli per chorda Strings Moduli per chorda Strings
VFD-PC10-7.5G-T4 18 2 15 2
VFD-PC10-11G-T4-MK 18 3 15 3

Tabula C. Specificationes generales (eadem trans range iMaster)

Item Specification
Rated frequency 50/60 Hz
Input frequency range ±5% (47.5 ad 63 Hz)
Output voltage 0 initus est voltage
Output frequency 0.1 ad 500 Hz
Maximam frequentiam 0 ad 500 Hz (SVC et V/F imperium)
Portitorem frequency 0,8 kHz ad 8 kHz, adaequatum statim ad onus (usque ad 16 kHz sustentatur)
Frequentia resolutio Digital setting 0.01 Hz; Analog occasum 0.025% of maximum frequency
Imperium modus Insipiens vector imperium (SVC); V/F imperium
Satus torques 0.5 Hz / 150% (SVC)
Celeritas range 1:100 (SVC)
Celeritas stabilitatis veritas ±0.5% (SVC)
ONERO facultatem 150% monetae æstimaturæ pro 60 s; 170% pro XII s; CXC% ad 1.5 s
Torque boost Automatic Aureus boost; manual boost 0.1% ad 30.0%
V/F curva Lineae, punctum multi- et curvae quadratae (1.2 / 1.4 / 1.6 / 1.8 / 2.0 potentiae)
V/F separation Plena separatio, dimidium separationis
Acceleratio / retardatio Linearibus vel S-curvis, 0.0 ad 6500.0 s
DC braking Committitur frequentia 0.00 Hz ad maximam frequentiam; tempus 0.0 ad 36.0 s; current 0.0% ad 100.0%
JOG imperium JOG frequentia 0.00 ad Hz frequentiam maximam (default 5 Hz); accel/decel 0.0 ad 6500.0 s
Inaedificata PID Ita, pressionis, fluxus vel temperatus ansa clausa sine exteriori moderatore
AVR Output voltage tenuit firmum, cum eget voltage fluctuat
Input terminals 5 digitalis inputs, DI5 sustinet pulsum venae altae usque ad 50 kHz; 1 analog input 0-10 V vel 0-20 mA; 1 keypad potentiometer input
Output terminals 1 pulsus summus velocitate output usque ad 50 kHz; Nullam 1 output; I Analog output 0-20 mA seu 0-10 V *
Communicationis RS485, Modbus RTU
Praesidium Motor brevis-circuitus deprehensio in potentia in, output phase damnum, super-currente, supra intentione, sub intentione, supra temperatura, onero, underload, lux debilis
operating temperatus -10°C ad 50°C; derate I% per I ° C supra XL ° C *
Repono temperatus -20°C ad 60°C
Umor Infra 95% RH, nulla condensatio
altitudo Infra M m; derate 1% per 100 m ab 1000 ad 3000 m
Vibratio Infra 5.9 m/s² (0.6 g)
clausura IP20, murus mons vel scrinium, vertical installation
Distributio systematis TN, TT
EMC / salus IEC 61800-3 (C3); IEC 61800-5-1

Solaris Pump operatio et malesuada euismod Tergum

Informatio series PC 10 automatariam seriem operativam describit ad institutiones quae ad potentiam solarem et elaborationem conformatae sunt. In configuratione documentis, parameter P8-15 eligit modum agendi modum. Cum P8-15 statuto ad 0, impulsio in potentia solaris operatur cum promptu et eget utitur secundum logicam debilem et mobilem conformatum.

Modulus informationis suppeditatus enumerat P8-16 ut intervallum craticulae, cum defalta 60 minutarum, et P8-17 ut mora coniungitur cum operatione solaris cum defalta 4 secundis. Confirmare consequentiam confirmatam et defaltam parametri contra manus manuales ad exemplar accuratum ac firmware versionis antequam committendum.

Ut ratio utens fonte AC tergum, ordinatio wiring et mutabilis sequi debet applicabilem ambitum schematis. Adfirmare an externa commutatione armorum requiratur; non assumo quod solus invertor omnem functionem permutationis fontium exerceat.

Imperium aqua-Level et Probe Cras

Ad copiae aquae communicatae, irrigationes et aquaculturae systemata, operatio sentinae ab utroque gradu aquae in piscina reposita et ad fontem aquae disponibilitate dependet. Parametri PC10 enumerantur munera praebent ad detectionem aquarum graduum pertinentes, vigilantia underload et culpa diagnostica explorandi.

Lacus Level Deprehensio

Parametri notitia suppeditata P8-18 agnoscit pro detectione aquarum AI, P8-19 pro limine plenae plano et P8-20 pro mora somni. Configuratus gradus signum et limen determinet quomodo coegi respondet condicione piscinae monitoriae. Sensorem type, wiring et ipsa seriei temperantiae sequentur applicabiles schematis et parametri instructiones.

Fonte-aqua et Underload Cras

Fons aquae tutelae informationis utitur P8-24 pro gradu deprehensionis underload, P8-25 ad tempus detectionis et P8-26 ad occasum reset. Haec parametri ad rem pertinent ubi deminutio oneris motoris adhibetur ad cognoscendum possibilem aquae defectum vel condicionem sentinam relatam.

Probe-culpam Opinio

Fons suppeditatus identificat P8-22 ut limen exploratorium vigilantia et E43 ut indicatio congruentis probe-culpae. Confirmare terrorem definitionis et detectionis condiciones in exemplar manuali tali pertinentes cum systematis figurandi vel sollicitudinis.

Aquarum gradus et functiones underload pendere a recta sensore delectu, institutione et uncinis parametris. Committantur et probentur sub condicionibus in documentis producti determinatis.

Imperium continuatio et remota Cras

Notitiarum seriei suppeditatae PC10 affirmat tabellas mandata et mandata communicationis per cyclum potentiam retineri posse. Mores actuales sileo cohibendus contra fontem mandatum conformatum, parametri sileo ac requisita applicationis tuta.

RS485 Modbus RTU recensetur ut instrumenti communicationis socialis. Fons spectat vigilantiam parametri U0-49 sicut status copiae, cum 0 demonstrans operationem eget et 1 operationem solarem demonstrans. Haec informationes possunt adhiberi per magnas rationes compatibles postquam definitionem registri confirmata et status valores praesto sunt in documentis communicationis applicabilibus.

Vigilantia remota utilis est cum coegi operatur ad piscinam aquae, stationem irrigationem vel alium situm ubi moderatoris non continue frequentatur. Communicatio paroecialis exploranda est ad confirmandum statum ostendens status actui operanti respondere.

General-Propositum Inverter Operation

In genere proposito modo, inversus inversus praebet imperium mobiles variabiles frequentiam pro instrumento compatibili. Modi moderandi recensiti sunt vectoris imperium sensorium (SVC) et imperium V/F, additis muneribus inclusis in PID constructis, accelerationis et retardationis accommodatae, JOG imperium et Modbus RTU communicatio.

Configuratio generalis-propositus considerari potest pro applicationibus compatibles quales sunt meae defusae, praedae pulvis suppressionis, circulatio industrialis et processus soleatus. Exemplar aequari debet cum currenti motori, onere notis, accelerationis requisitis et officio operante.

Parameter P8-00 notatur in informationibus suppeditatis sicut modulus operandi modus lectionis. Modus configurari debet secundum applicationem actualem ac instructiones ad exemplar instructum. Quaelibet mutatio inter sentinam solarem et operationem generalem propositum sequi debet modulo praescriptorum et agendi modum committendi.

Typical Applications

1. Community et Village Aquae Supple

Nam borehole vel aquae fluvii ad piscinam distribuendam, operandi solaris agitati et munera libraria vigilantia recensita considerari possunt ut pars de consilio systematis. Motor rating, caput flare, aquae volumen requiri et imperium cisternina gradu definiri debet antequam coegi est electus.

2. Africa Cooperatives et Shared Pump Stations

Systemata irrigationis communis uti potest sentinam centralem ut multiplices agros vel irrigationes zonis praebeat. Electio considerare debet requisitum caput dynamicum, totalem caput dynamicum, schedulam cotidianam operantem et disponibilitatem potentiae solaris vel craticulae.

3. Piscium et Alpheus Farms

Aquarum commutatio et circulatio soleatus ad sites aquaculturae variabiles-frequentiis uti possunt, ubi dispositio motoris et sentinae compatiuntur. In schedula requisita flare et moderatorum aquarum procuratio considerari debent una cum copia situs potentiae.

4. Mea et Lapicidina Aqua Management

In communi-proposito modo, coegi aestimari potest pro compatible mea destillatio, fovea aquae administratio et pulvis suppressionis elit instrumenti. Cognoscere motorem rating, onerarias condiciones, environmental requisita et modum temperandi ad specificam institutionem requirendam.

5. Circulation Industrial et Refrigerium

Configuratio generalis propositi considerari potest pro processu compatibilis circulationis aquae, refrigerationis turris et aliorum officiorum flantium industrialium. Requisitus fluxus, pressionis operativae et notae motoriae aestimandae sunt ut pars consilii systematis.

Technical Specifications

Item Specification
Rated frequency 50/60 Hz
Input frequency range ±5% (47.5 ad 63 Hz)
Output voltage 0 initus est voltage
Output frequency 0.1 ad 500 Hz
Maximam frequentiam 0 ad 500 Hz (SVC et V/F imperium)
Portitorem frequency 0,8 kHz ad 8 kHz, automatice adaequatum onerant; usque ad XVI kHz suscepit
Frequentia resolutio Digital setting 0.01 Hz; Analog occasum 0.025% of maximum frequency
Imperium modus Insipiens vector imperium (SVC); V/F imperium
Satus torques 0.5 Hz / 150% (SVC)
Celeritas range 1:100 (SVC)
Celeritas stabilitatis veritas ±0.5% (SVC)
ONERO facultatem 150% monetae æstimaturæ pro 60 s; 170% pro XII s; CXC% ad 1.5 s
Torque boost Automatic Aureus boost; manual boost 0.1% ad 30.0%
V/F curva Lineae, punctum multi- et curvae quadratae (1.2 / 1.4 / 1.6 / 1.8 / 2.0 potentiae)
V/F separation Plena separatio, dimidium separationis
Acceleratio / retardatio Linearibus vel S-curvis, 0.0 ad 6500.0 s
DC braking Committitur frequentia 0.00 Hz ad maximam frequentiam; tempus 0.0 ad 36.0 s; current 0.0% ad 100.0%
JOG imperium JOG frequentia 0.00 ad Hz frequentiam maximam (default 5 Hz); accel/decel 0.0 ad 6500.0 s
Inaedificata PID Ita, pressionis, fluxus vel temperatus ansa clausa sine exteriori moderatore
AVR Output voltage tenuit firmum, cum eget voltage fluctuat
Input terminals 5 digitalis inputs, DI5 sustinet pulsum venae altae usque ad 50 kHz; 1 analog input 0-10 V vel 0-20 mA; 1 keypad potentiometer input
Output terminals 1 pulsus summus velocitate output usque ad 50 kHz; Nullam 1 output; I Analog output 0-20 mA seu 0-10 V *
Communicationis RS485, Modbus RTU
Praesidium Motor brevis-circuitus deprehensio in potentia in, output phase damnum, super-currente, supra intentione, sub intentione, supra temperatura, onero, underload, lux debilis
operating temperatus -10°C ad 50°C; derate I% per I ° C supra XL ° C *
Repono temperatus -20°C ad 60°C
Umor Infra 95% RH, nulla condensatio
altitudo Infra M m; derate 1% per 100 m ab 1000 ad 3000 m
Vibratio Infra 5.9 m/s² (0.6 g)
clausura IP20, murus mons vel scrinium, vertical installation
Distributio systematis TN, TT
EMC / salus IEC 61800-3 (C3); IEC 61800-5-1

Clausura IP20 aestimatur et tutelam contra aquarum introitum non praebet. Coegi debet institui in ambitus clausurae tectis vel tutelae convenienti congrua evacuatione et secundum eius temperiem, humiditatem et institutionem requisita.

Frequenter Interrogata

1. Quantum PV ordinatae ponitur pro exemplo 11 kW?

Figurarum referentiae suppeditatae denotant tres chordarum 18 modulorum qui in 250 Wp aestimantur vel tres chordarum 15 modulorum CCC Wp aestimantur. Hae dispositiones respondent 54 moduli vel 45 moduli, respective, et computata vis nominalis ordinata 13.5 kWp utrobique. Consilium chordae finalis verificabitur contra notae moduli, situs minimum temperatus et fines invertentis DC voltage.

2. Num 65 dBA rating clausura acustica medium requiri videtur?

Suppletum specificatio maximum strepitum graduum 65 dBA enumerat. Utrum curatio acustica accessio necessaria sit ex institutione locationis, camera acustici, instrumenti operandi et applicatio strepitus requisitorum. Considera institutionem ambitum cum positio coegi in opere occupato aedificio vel incluso instrumento cubiculi.

3. Potest aliquis coegi currere plures soleatus?

Configuratio generalis propositi coniungi debet toti oneri et methodo sustentata temperantiae. Ad applicationes vector-control, applicabilem ordinationem motoris in manuali confirmamus. Currens multiplex motores ab uno coegi requirit coniunctum currentem manere intra rating coegi et unumquodque mobilem habere opportunitatem onerare tutelam. Sequi fabrica instructiones ad modum imperii delecti.

4. Quomodo fons potentiae hodiernae viverra potest?

Informatio suppeditata vigilantiam parametri U0-49 agnoscit sicut indicator modus suppletionis, cum 0 operandi egetis repraesentans et 1 operationem solarem repraesentans. Parameter legi potest supra Modbus RTU ubi subnixa. Confirmare rationem registri definitionis et communicationis occasus contra manuales applicabiles antequam eam in systemate vigilantia remota integrant.

5. Quae exercitatione sustentatio requiritur?

Serva heatsink et refrigerationem ventilabrum lucidum pulveris, nexus inspice terminales et wiring secundum sustentationem schedulae, et monitor ambientis temperiem et evacuationem. Temperatura operativa inscripta range est -10°C ad 50°C, cum supra 40°C. Directio altitudinis suppeditatae etiam dat speciem supra 1000 m. Intervalla et rationes inspiciendarum rationum conservationum exempla accurata instructiones sequere.

6. Estne hic inversus limitatus ad flare solaris?

No. Series informationum suppeditatorum PC10 enumeratarum sentinae solaris modum et modum invertentis generalis propositi. Solaris operatio sentinarum MPPT includit et documenta crepitans functiones tutelae relatas includit, dum operatio generalis propositi SVC vel V/F imperium motoris sustinet, PID et Modbus RTU. Parameter P8-00 notus est ac modus electionis modulus. Confirmare licet occasum ac modum-mutationis procedendi in manuali speciali exemplari.

Mitte Inquisitionem
Contactus info

Si inquisitionem habes de quotation vel de cooperatione, placet liberum contactus nobis electronicum facere in sanchia@csivei.com vel sequenti forma inquisitionis utere. Repraesentator venditio nostra intra 24 horas contact erit. Gratias tibi ago pro cura tua in productis nostris.


Whatsapp:8615705777705

Tela:www.csiveivfd.com


X
Crusulis utimur ut meliorem experientiam pasco tibi praebeamus, situm negotiationis et personalize contentus analyse. Hoc situ utendo, ad nostrum crustulorum usum consentis. Privacy Policy
RejectAccipe